Fire Alarm Control Unit(JB-TGL-EI8000G/JB-TTL- EI6000T)
Product Overview:



Overview:

 EI8000G/ EI8000T fire alarm controller (linkage type) integrates various functions such as fire alarm, linkage control, supervision alarm, anti-theft alarm, flammable gas alarm, intercom telephone,network communication, etc. It is suitable for all kinds of hotels, office buildings .Large and medium-sized fire alarm projects such as buildings, residential buildings, gymnasiums, libraries, and various warehouses.

 


Basic Functions:

Fire alarm functioncan receive fire alarm signals through fire detectors such as smoke detectors, heat detectors, relay modules, manual call point, etc., and display fire alarm information. Composite        judgment can be made based on adjacent detectors.

Supervision alarm function: can receive the supervision alarm signals such as burglary alarm and gas alarm through the input module, and can realize linkage.

Shielding function: can shield various bus components and the fire sound strobe alarm output.

Fault detection function: can automatically detect line faults, component faults, power faults, etc., and issue fault alarms with sound and light signals to display fault information.

System test function: can log in part number and current address, can directly set and program address; can check detector detection value; Ability to self-test any part of the loop.


Special Functions:

Linkage control function: The EI series input/output modules can be connected via four buses (including 24V power lines), and various types of fire-fighting equipment can be controlled in a flexible and diverse manner according to the alarm information, and the linkage points are not limited, and the user's needs can be met to the maximum extent. Displays feedback information about device actions, including device type, module type, module address, installation location, and action time.

Optional bus linkage control panel, through programming can realize control of various types, zones, and specific components.

Optional multi-line linkage control panel, direct output linkage control, 12 sets of multi-line linkage buttons for each control panel, used to control important equipment such as fire pump, spray pump and exhaust fan. When the multi-line linkage panel exceeds 2 blocks, the external control power supply needs to be configured for the power supply of the multi-line linkage panel.

Be provided with gas fire extinguishing function, gas fire extinguishing equipment can be connected by bus to realize manual/automatic

Manual/automatic switching is possible. in the manual state, any device can be started or stopped by type, partition or address through menu selection.

System compatible function: It can be set as a centralized controller, zone controller or independent fire alarm controller on site, and can form a network communication system through EICAN/EINet?.

The zones controller can automatically upload fire alarm, linkage control, fault alarm, supervision alarm, shielding, delay, self-test and other information to the centralized controller, and should be able to receive and process the relevant instructions of the centralized controller.

The centralized controller can receive and display fire alarm, linkage control, fault alarm, supervision alarm, shielding, delay, self-test and other information from each zone controller, enter the corresponding state, and can issue control commands to the area controller.

Network communication function: It can connect zones alarm controller, centralized alarm controller and fire control room graphic display device to realize local area network communication through EINet/EICAN; it has RS-232/485 serial communication interface, which can be connected with building automation or other systems, remote communication can be carried out through our remote monitoring system.

Programming function: It can complete all programming through the keyboard of the controller itself, can input Chinese characters directly, and has built-in secondary standard Chinese character font. It can be used for annotation of Chinese characters in any device in the system and its location. It is very intuitive; it has extremely convenient screen editing function. Can automatically prompt for the location of the data error and give the correct range of data.


Auxiliary functions:

Black box function: It can automatically store historical records such as fire alarm, warning, supervision, linkage, fault, shielding, etc.

Query function: It can query all fire alarm, warning, supervision, linkage, fault, shielding and programming information, and can query the required information in the most convenient way.

Print function: It can automatically print real-time fire alarm, warning, supervision information and linkage action information, and can print parts list.

Automatic switching between main and backup power: It can automatically switch between main and standby power, and has corresponding indications. The backup power has undervoltage protection function to avoid damage to the battery due to excessive discharge.

Operation authority: In order to prevent unintentional personnel from misoperation, the operation level can be limited by password, and the password can be set arbitrarily.















 





 





? Ambient temperature: 0 °C ~ 40 °C; Relative humidity: ≤ 95 % (non-condensing)

? AC input voltage: 220V±10/15%?, 50Hz±1%

? AC input power: ≤240W

? DC backup: DC24V/24Ah fully sealed maintenance free battery

? Maximum loop capacity: 242 addressing points

? Maximum total capacity: 4840 addressing points

? Number of multi-line linkage control panels: ≤10 (each linkage panel has 12 sets of multi-line linkage buttons)

? Number of bus linkage control panels: ≤ 20 (60 buttons per panel)

? Bus length: ≤ 2000 meters (cross-sectional area ≥ 1.0mm2)

?Dimensions:545mm*485mm*1800mm( cabinet type)          

1080mm*1120mm*1250mm (6000T piano type)


    


Back
Contact Us
eifire@eifire.com
400-0552-119
Contact Us400-0552-119
Follow Us Follow Us
主站蜘蛛池模板: 91黑丝大长腿你视频里见过我 | 91青青视频 | 欧洲vodawifi喷浆3d | 成人性生交大片在线观看 | 国产精品自在线拍国产第一页 | 午夜亚洲在在线观看 | 2025国产精品网站在线播放 | 国产日韩欧美高清一区二区三区 | 中国挤奶哺乳午夜片 | 美女人妖极品入口免费观看视频 | 不卡人人中文字幕jul975老公 | 亚洲熟 女毛茸茸 | 91制片厂果冻传媒京东影业 | 国产又粗又黄又爽又硬 | 国产交涩| 91精品国产露 | 免费的成年私人影院网站 | 91永久入口t一区二区 | 天堂之吻动漫在线观看完 | 3d动漫精品一区二区在线播放 | 中文字幕一二三 | 亚洲久优优色优在线播放 | 国产自产一区二区三区视频在线 | 综合五月激情二区视频 | 亚洲日韩中 | 伊人性情综合网 | 视频一区二区免费国产在线观看 | 国产尤物精品视频午夜版 | 日本亚洲欧美国产日韩ay高清 | 国产精品水多 | 国产91影院 | 8x国产精品视频一区二区 | 国产在线不卡精品 | 成人a级高清视频在线观看 国产视频你懂得 | 色综合天天视频在线观看 | 爱豆传媒mv在线看 | 91精品国产人成网站 | 99国产精品偷窥熟女精品视频 | 日韩视频中文字幕视频一区 | 成人淫秽视频在线播放免费 | 精品日韩一区二区视频在线 |